-40%

OHAUS MB120 Moisture Analyzer Halogen Lamp 120g x 1mg Make Offer 2Y Warranty

$ 2291.12

Availability: 10 in stock
  • Brand: Ohaus Corporation
  • Condition: New
  • All returns accepted: Returns Accepted
  • MPN: 30241165
  • Item must be returned within: 30 Days
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Model: MB 120
  • Return shipping will be paid by: Buyer

    Description

    Moisture Analysis Made Simple—and Powerful.
    The MB120 delivers functionality and precision that you can rely on, and is easy to operate and clean—you can test more samples in less time! Advanced features such as a temperature guide help to analyze optimum drying temperature, and methods and results storage allows statistical analysis of measurements. Three levels of user management ensure data safety—set up and lock temperature settings and method parameters with administrator access.
    Standard Features Include:

    Advanced Functionality for Professional Moisture Analysis
    MB120’s Temperature Guide analyzes a sample and determines the optimal drying temperature. Store up to 100 drying methods for easy recall and up to 1000 total results for statistical analysis.

    Precise and Fast Results with Halogen Heating Increases Efficiency in the Lab
    Precisely controlled halogen heating dries samples uniformly, producing repeatable results of 0.01% readability. Four drying profiles and seven shut-off criteria help to perform customized sample tests.

    Easy Tool-Free Cleaning and Intuitive Operation with the Icon-Driven Menu Navigation
    The MB120 features a removable pan handler and sample chamber for easy cleaning. Operating the MB120 is intuitive—simply follow the guided instructions on the touchscreen display. The robust housing and die-cast base guarantee
    durability.
    MB120
    Moisture Analyzer
    Advanced Functionality
    Test a wide variety of materials for a
    range of applications with MB120.
    Temperature Guide
    Easily analyze a sample of a specific material and determine the optimum drying temperature.
    100 Methods Library Makes Testing Faster
    Program the parameters for up to 100 different types of samples, then select and run your test with the push of a button.
    Store Up to 1000 Results for All Methods for Statistical Analysis
    Quickly retrieve data and save to flash drive.
    Three-Level User Management
    Set up and lock temperature settings and method parameters with admin access, so users can’t modify settings.
    Testing Made Simple
    The MB Series features a wide, bright touchscreen display and intuitive menu navigation for fast, accurate moisture analysis.
    Touchscreen Display
    Easy to read and understand
    Icon-Driven Menu Navigation
    Easy to follow — no training required
    4 Mechanical Keys for Fast One-Step Operation
    Tare, Start/Stop, Print, On/Off
    USB and RS232 Ports
    Quick connections to a PC or flash drive
    Moisture Analysis Made Simple
    Just 3 easy steps for routine sample testing!
    1.
    Tare empty sample pan
    2.
    Add sample according to best practices
    3.
    Press start and see your results!
    Exceptional Precision
    The MB120 provides precise results for
    more confident testing.
    Fast Halogen Heating Technology
    Halogen heating dries samples in seconds and performs up to 40% faster than traditional infrared methods.
    Uniform Drying for Precise, Repeatable Results
    The reflective sample chamber ensures uniform heating of each sample to yield reliable results of 0.01% readability.
    Flexible and Powerful
    Features a full operating temperature range of 40–230 °C in 1 degree increments.
    Four Drying Profiles to Ensure Accuracy
    Customize heating of specific samples with temperature control for one-step drying—set temperature and time and begin!
    Fast:
    Quickest possible time to temperature
    Standard:
    Minimal overshoot while achieving
    temperatures quickly
    Ramp:
    Controlled ramping to temperatures
    Step:
    Set three temperatures at three time intervals
    Shut-Off Criteria for Automatic Test Completion
    Customize your own test endpoint criteria to automatically end the test once moisture loss is no longer detected. Choose from 7 criteria—Manual, Timed, AutoFree percent weight loss per second, AutoFree mg loss per second, A30, A60 and A90.
    asy Tool-Free Cleaning
    The MB120 features a patented pan handler and removable parts for convenient maintenance.
    Stainless Steel Drying Pan
    Wipe down quickly
    Removable Heating Chamber Components
    No tools required—simply remove glass and tray to clean
    Product Specifications
    Maximum Capacity
    120 g
    Readability Moisture Content
    1 mg/0.01%
    Pan Size (Ø_Diameter)
    90.0 mm (3.5 in)
    Heater Type
    Halogen Lamp
    Dimensions (Width)
    211.0 mm (8.31 in)
    Dimensions (Length)
    355.0 mm (13.98 in)
    Net Weight
    5.23 kg (11.53 lb)
    Test Weight
    50g, OIML F2 or ASTM CL 4
    Dimensions (Height)
    180.0 mm (7.09 in)
    Temperature Range
    40 °C – 230 °C
    Working Environment
    10°C – 40°C, 85%RH, non-condensing
    Operating Range (Temp.)
    10 °C – 40 °C
    Shut-Off Criteria
    Manual;
    Timed;
    Automatic - Preset Weight Loss/Time;
    Custom - User Set Weight Loss/Time;
    Custom-User Set Moisture% Loss/Time
    Power
    115 v, 60 Hz
    Display
    Full-Color 4.3 in Touchscreen WQVGA
    Working Environment
    50°F – 104°F, 85%RH, non-condensing
    In-use cover
    Included
    Moisture Range
    0 % – 100 %
    Test Library
    100
    Heating Profiles
    Standard;
    Ramp;
    Step;
    Fast
    Sample Size
    0.5 g – 120 g