-40%

*NEW* Fluke 85RF High Frequency Probe 500 MHZ

$ 46.99

Availability: 35 in stock
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 14 Days
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Restocking Fee: No
  • Condition: New

    Description

    New Fluke
    85RF
    High Frequency Probe 500 MHz
    Brand new Fluke 85RF High Frequency Probe, with accessories and instruction sheet.
    Voltage Range:
    0.25 to 30V rms
    Maximum Input Voltage:
    30V rms, 200V dc
    AC to DC Ratio:
    1:1
    Ratio Accuracy (At 25 MHz and loaded with 10 M ohm) Above 0.5V:
    +/- 0.5 dB | Below 0.5V: +/- 1.0 dB | Add +/- 0.2 dB in RF fields of 1 to 3 V/m
    Frequency Response (Relative to 25 MHz):
    100KHz to 100 MHz +/- 0.5 dB | 100 MHz to 200 MHz +/- 2.0 dB | 200 MHz to 500 MHz +/- 3.0 dB
    The 85RF High Frequency Probe is designed to convert a DC voltmeter with a input impedance of 10M ohms into a high frequency (100kHz to 500Mhz) RF voltmeter. Conversion from AC to DC is accomplished on a one-to-one basis includes a range of 0.25 to 30V rms. The probe’s DC output is calibrated to be equivalent to the rms value of a sine wave input.